
{"id":186,"date":"2020-10-21T08:03:00","date_gmt":"2020-10-21T06:03:00","guid":{"rendered":"https:\/\/blog.proclima.com\/suisse\/?p=186"},"modified":"2020-07-31T20:50:44","modified_gmt":"2020-07-31T18:50:44","slug":"risques-particuliers-lors-de-la-renovation-7-8","status":"publish","type":"post","link":"https:\/\/blog.proclima.com\/suisse\/2020\/10\/21\/risques-particuliers-lors-de-la-renovation-7-8\/","title":{"rendered":"Risques particuliers lors de la r\u00e9novation (7\/8)"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">R\u00e9alisation intelligente et efficace des raccords (7\/8) \u2013 Risques particuliers lors de la r\u00e9novation<\/h2>\n\n\n\n<p><em>Suite de la section 6: <a href=\"https:\/\/blog.proclima.com\/suisse\/?p=179\">Un probl\u00e8me des fen\u00eatres de toiture en pente&nbsp;: le collage des coins<\/a><\/em><\/p>\n\n\n\n<p><strong>L\u2019\u00e9tanch\u00e9it\u00e9 \u00e0 l&rsquo;air<\/strong> est particuli\u00e8rement d\u00e9licate \u00e0 r\u00e9aliser <strong>lors de la r\u00e9novation,<\/strong> parce que bien souvent, les murs ne sont pas droits et les supports in\u00e9gaux. Lors des travaux d\u2019assainissement, on cr\u00e9e alors volontiers une nouvelle surface impeccable, en y fixant un rev\u00eatement l\u00e9ger en placopl\u00e2tre. Mais la plupart du temps sans s\u2019\u00eatre pr\u00e9occup\u00e9 auparavant des <strong>d\u00e9fauts d\u2019\u00e9tanch\u00e9it\u00e9 dans l\u2019enveloppe du b\u00e2ti,<\/strong> comme la ma\u00e7onnerie apparente.<\/p>\n\n\n\n<!--more-->\n\n\n\n<p>De l\u2019air risque de circuler derri\u00e8re ces constructions qui n\u00e9cessitent donc une r\u00e9fection pr\u00e9alable. La consigne est claire&nbsp;: enduire, puis rev\u00eatir. Il suffit d\u2019appliquer un enduit lisse sur les zones apparentes ou poreuses de la ma\u00e7onnerie <strong>pour \u00e9viter les flux d\u2019air.<\/strong> En remplacement, on peut notamment aussi appliquer un <a href=\"https:\/\/ch-fr.proclima.com\/produits\/assemblage\/etancheite-liquide\">enduit d&rsquo;\u00e9tanch\u00e9it\u00e9 synth\u00e9tique pulv\u00e9risable<\/a> sur toute la surface ma\u00e7onn\u00e9e. Notons que l\u2019on peut augmenter la fiabilit\u00e9 de la construction en effectuant en cours de r\u00e9novation un test d\u2019infiltrom\u00e9trie (BlowerDoor) qui y d\u00e9c\u00e8le t\u00f4t assez les d\u00e9fauts d\u2019\u00e9tanch\u00e9it\u00e9 existants.<\/p>\n\n\n\n<p style=\"background-color:#ffe9e9\" class=\"has-background\">Cette s\u00e9rie d\u2019articles r\u00e9sume des situations de raccords typiques et difficiles, tout en montrant aux artisans comment les r\u00e9soudre en pratique. Par ailleurs, elle donne un aper\u00e7u des solutions pr\u00e9fabriqu\u00e9es qui existent pour certains points singuliers et qui permettent aux artisans une r\u00e9alisation rapide, facile et fiable de l&rsquo;\u00e9tanch\u00e9it\u00e9 \u00e0 l&rsquo;air.<\/p>\n\n\n\n<figure class=\"wp-block-gallery columns-2 is-cropped wp-block-gallery-1 is-layout-flex wp-block-gallery-is-layout-flex\"><ul class=\"blocks-gallery-grid\"><li class=\"blocks-gallery-item\"><figure><img loading=\"lazy\" decoding=\"async\" width=\"474\" height=\"648\" data-size=\"474x648\" src=\"https:\/\/blog.proclima.com\/suisse\/files\/2020\/07\/luftdichtung-verkleidete-baustelle.jpg\" alt=\"\" data-id=\"154\" data-full-url=\"https:\/\/blog.proclima.com\/suisse\/files\/2020\/07\/luftdichtung-verkleidete-baustelle.jpg\" data-link=\"https:\/\/blog.proclima.com\/suisse\/luftdichtung-verkleidete-baustelle\/\" class=\"wp-image-154\" srcset=\"https:\/\/blog.proclima.com\/suisse\/files\/2020\/07\/luftdichtung-verkleidete-baustelle.jpg 474w, https:\/\/blog.proclima.com\/suisse\/files\/2020\/07\/luftdichtung-verkleidete-baustelle-219x300.jpg 219w\" sizes=\"auto, (max-width: 474px) 100vw, 474px\" \/><\/figure><\/li><li class=\"blocks-gallery-item\"><figure><img loading=\"lazy\" decoding=\"async\" width=\"472\" height=\"644\" data-size=\"472x644\" src=\"https:\/\/blog.proclima.com\/suisse\/files\/2020\/07\/lufteintritt-installation.jpg\" alt=\"\" data-id=\"155\" data-full-url=\"https:\/\/blog.proclima.com\/suisse\/files\/2020\/07\/lufteintritt-installation.jpg\" data-link=\"https:\/\/blog.proclima.com\/suisse\/lufteintritt-installation\/\" class=\"wp-image-155\" srcset=\"https:\/\/blog.proclima.com\/suisse\/files\/2020\/07\/lufteintritt-installation.jpg 472w, https:\/\/blog.proclima.com\/suisse\/files\/2020\/07\/lufteintritt-installation-220x300.jpg 220w\" sizes=\"auto, (max-width: 472px) 100vw, 472px\" \/><\/figure><\/li><\/ul><figcaption class=\"blocks-gallery-caption\">L\u2019an\u00e9mom\u00e8tre indique une entr\u00e9e d\u2019air de respectivement 2,78 et 1,86 m\u00e8tres par seconde au niveau des bo\u00eetiers de l\u2019installation \u00e9lectrique. Mais la vraie cause se situe derri\u00e8re, cach\u00e9e par les plaques en placopl\u00e2tre. Gr\u00e2ce \u00e0 une d\u00e9tection des fuites en cours de r\u00e9novation, avant la pose du rev\u00eatement, de tels d\u00e9fauts d&rsquo;\u00e9tanch\u00e9it\u00e9 \u00e0 l&rsquo;air deviennent visibles et peuvent \u00eatre \u00e9limin\u00e9s plus facilement.<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"633\" height=\"355\" data-size=\"633x355\" src=\"https:\/\/blog.proclima.com\/suisse\/files\/2020\/07\/sprueh-dichtung-aerosana-visconn.jpg\" alt=\"\" class=\"wp-image-157\" srcset=\"https:\/\/blog.proclima.com\/suisse\/files\/2020\/07\/sprueh-dichtung-aerosana-visconn.jpg 633w, https:\/\/blog.proclima.com\/suisse\/files\/2020\/07\/sprueh-dichtung-aerosana-visconn-300x168.jpg 300w, https:\/\/blog.proclima.com\/suisse\/files\/2020\/07\/sprueh-dichtung-aerosana-visconn-352x198.jpg 352w\" sizes=\"auto, (max-width: 633px) 100vw, 633px\" \/><figcaption>Les supports rugueux ou poussi\u00e9reux peuvent \u00eatre pr\u00e9par\u00e9s avec <a href=\"https:\/\/ch-fr.proclima.com\/produits\/assemblage\/etancheite-liquide\">AEROSANA VISCONN<\/a> pour le collage ult\u00e9rieur des rubans adh\u00e9sifs pro clima. Pour cela, appliquer une couche couvrante de film pulv\u00e9ris\u00e9.<\/figcaption><\/figure>\n\n\n\n<div class=\"wp-block-group has-subtle-background-background-color has-background\"><div class=\"wp-block-group__inner-container is-layout-flow wp-block-group-is-layout-flow\">\n<h3 class=\"wp-block-heading\">Vue d&rsquo;ensemble de la s\u00e9rie<\/h3>\n\n\n\n<ol class=\"wp-block-list\"><li><a href=\"https:\/\/blog.proclima.com\/suisse\/?p=125\">Fuite typique: passages de c\u00e2bles dans le cas d&rsquo;installations \u00e9lectriques<\/a> <\/li><li><a href=\"https:\/\/blog.proclima.com\/suisse\/?p=162\">Un d\u00e9fi: l\u2019\u00e9tanch\u00e9it\u00e9 autour des faisceaux de c\u00e2bles<\/a> (12.08.2020)<\/li><li><a href=\"https:\/\/blog.proclima.com\/suisse\/?p=169\">Un d\u00e9fi: les c\u00e2bles sur une poutre<\/a> (26.08.2020)<\/li><li><a href=\"https:\/\/blog.proclima.com\/suisse\/?p=172\">Un d\u00e9fi: les passages de conduits<\/a> (09.09.2020)<\/li><li><a href=\"https:\/\/blog.proclima.com\/suisse\/?p=177\">Prudence avec les coins des fen\u00eatres en mati\u00e8re synth\u00e9tique<\/a> (23.09.2020)<\/li><li><a href=\"https:\/\/blog.proclima.com\/suisse\/?p=179\">Un probl\u00e8me des fen\u00eatres de toiture en pente: le collage des coins<\/a> (07.10.2020)<\/li><li><a href=\"https:\/\/blog.proclima.com\/suisse\/?p=186\">Risques particuliers lors de la r\u00e9novation<\/a> (21.10.2020)<\/li><li><a href=\"https:\/\/blog.proclima.com\/suisse\/?p=189\">Vieilles solives en cas de r\u00e9novation<\/a> (04.11.2020)<\/li><\/ol>\n\n\n\n<p><\/p>\n<\/div><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">Informations compl\u00e9mentaires<\/h3>\n\n\n\n<ul class=\"wp-block-list\"><li>Conseil de lecture&nbsp;: <a href=\"https:\/\/ch-fr.proclima.com\/produits\/assemblage\/etancheite-liquide\">Le syst\u00e8me AEROSANA VISCONN : pulv\u00e9risation facile du frein-vapeur et de l\u2019\u00e9tanch\u00e9it\u00e9 \u00e0 l&rsquo;air<\/a><\/li><li>Conseil vid\u00e9o&nbsp;: <a href=\"https:\/\/blog.proclima.com\/de\/2019\/11\/luftdichtung-macht-sinn\/\">L\u2019\u00e9tanch\u00e9it\u00e9 \u00e0 l\u2019air \u00e0 100&nbsp;%&nbsp;: est-ce bien sens\u00e9&nbsp;? Et est-ce vraiment possible dans les constructions anciennes&nbsp;?<\/a><\/li><li>Conseil vid\u00e9o&nbsp;: <a href=\"https:\/\/www.youtube.com\/watch?v=4rDX5L64OkI\">Restaurateur et ma\u00eetre-charpentier&nbsp;: nouvelle construction et r\u00e9novation&nbsp;: les points singuliers sont-ils importants&nbsp;?<\/a><\/li><\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Cette s\u00e9rie d&rsquo;articles a \u00e9t\u00e9 r\u00e9dig\u00e9e par Jens L\u00fcder Herms et Holger Merkel.<\/h3>\n\n\n\n<div class=\"wp-block-media-text alignwide is-stacked-on-mobile\" style=\"grid-template-columns:23% auto\"><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"360\" height=\"540\" data-size=\"360x540\" src=\"https:\/\/blog.proclima.com\/suisse\/files\/2020\/07\/Jens-Lueder-Herms.jpg\" alt=\"\" class=\"wp-image-146\" srcset=\"https:\/\/blog.proclima.com\/suisse\/files\/2020\/07\/Jens-Lueder-Herms.jpg 360w, https:\/\/blog.proclima.com\/suisse\/files\/2020\/07\/Jens-Lueder-Herms-200x300.jpg 200w\" sizes=\"auto, (max-width: 360px) 100vw, 360px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<p>Jens L\u00fcder Herms, charpentier et ing\u00e9nieur dipl\u00f4m\u00e9 (HES), directeur des exportations et ing\u00e9nieur sp\u00e9cialis\u00e9 en applications, pro clima Recherche et D\u00e9veloppement, <a href=\"https:\/\/ch-fr.proclima.com\">https:\/\/ch-fr.proclima.com<\/a>.<br>Vous trouverez des illustrations de son travail sur <a href=\"https:\/\/twitter.com\/luederHerms\">Twitter<\/a> et <a href=\"https:\/\/www.instagram.com\/jens.lueder.herms\/\">Instagram.<\/a><\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-media-text alignwide has-media-on-the-right is-stacked-on-mobile\" style=\"grid-template-columns:auto 25%\"><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"292\" height=\"436\" data-size=\"292x436\" src=\"https:\/\/blog.proclima.com\/suisse\/files\/2020\/07\/Holger-Merkel.jpg\" alt=\"\" class=\"wp-image-145\" srcset=\"https:\/\/blog.proclima.com\/suisse\/files\/2020\/07\/Holger-Merkel.jpg 292w, https:\/\/blog.proclima.com\/suisse\/files\/2020\/07\/Holger-Merkel-201x300.jpg 201w\" sizes=\"auto, (max-width: 292px) 100vw, 292px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<p>Holger Merkel, fournisseur de services d\u2019infiltrom\u00e9trie BlowerDoor, conf\u00e9rencier de <a href=\"https:\/\/kaenguru.me\/\">l\u2019atelier p\u00e9dagogique<\/a> pro clima et formateur de cours de certification. Dans le cadre de son tout nouveau projet <a href=\"https:\/\/www.zieht-wie-hechtsupp.de\/\">www.zieht-wie-hechtsupp.de,<\/a> il d\u00e9taille la probl\u00e9matique des fuites. Sur le site <a href=\"https:\/\/www.airtight-junkies.de\/\">www.airtight-junkies.de,<\/a> il publie entre autres des articles sp\u00e9cialis\u00e9s sur les tests d\u2019infiltrom\u00e9trie (BlowerDoor).<\/p>\n<\/div><\/div>\n","protected":false},"excerpt":{"rendered":"<p>R\u00e9alisation intelligente et efficace des raccords (7\/8) \u2013 Risques particuliers lors de la r\u00e9novation Suite de la section 6: Un probl\u00e8me des fen\u00eatres de toiture <a href=\"https:\/\/blog.proclima.com\/suisse\/2020\/10\/21\/risques-particuliers-lors-de-la-renovation-7-8\/\" rel=\"bookmark\">&#8230;<\/a><\/p>\n","protected":false},"author":40,"featured_media":157,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[2,1],"tags":[26,28,19,21,24,20,14,15,16,23,25,18],"class_list":["post-186","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-letancheite-a-lair","category-proclima","tag-colles","tag-constructions-anciennes","tag-enveloppe-du-bati","tag-etancheite-a-lair","tag-frein-vapeur","tag-installation-electrique","tag-passages","tag-points-singuliers-de-raccords","tag-raccord-aux-elements-de-construction","tag-raccord-etanche-a-lair","tag-renovation","tag-solutions-pour-points-singuliers"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Risques particuliers lors de la r\u00e9novation (7\/8) - blog pro clima Suisse<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/blog.proclima.com\/suisse\/2020\/10\/21\/risques-particuliers-lors-de-la-renovation-7-8\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Risques particuliers lors de la r\u00e9novation (7\/8) - blog pro clima Suisse\" \/>\n<meta property=\"og:description\" content=\"R\u00e9alisation intelligente et efficace des raccords (7\/8) \u2013 Risques particuliers lors de la r\u00e9novation Suite de la section 6: Un probl\u00e8me des fen\u00eatres de toiture ...\" \/>\n<meta property=\"og:url\" content=\"https:\/\/blog.proclima.com\/suisse\/2020\/10\/21\/risques-particuliers-lors-de-la-renovation-7-8\/\" \/>\n<meta property=\"og:site_name\" content=\"blog pro clima Suisse\" \/>\n<meta property=\"article:published_time\" content=\"2020-10-21T06:03:00+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/blog.proclima.com\/suisse\/files\/2020\/07\/sprueh-dichtung-aerosana-visconn.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"633\" \/>\n\t<meta property=\"og:image:height\" content=\"355\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Nils Braune\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\" \/>\n\t<meta name=\"twitter:data1\" content=\"Nils Braune\" \/>\n\t<meta name=\"twitter:label2\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/blog.proclima.com\\\/suisse\\\/2020\\\/10\\\/21\\\/risques-particuliers-lors-de-la-renovation-7-8\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/blog.proclima.com\\\/suisse\\\/2020\\\/10\\\/21\\\/risques-particuliers-lors-de-la-renovation-7-8\\\/\"},\"author\":{\"name\":\"Nils Braune\",\"@id\":\"https:\\\/\\\/blog.proclima.com\\\/suisse\\\/#\\\/schema\\\/person\\\/867d432d923c4986caa239ecb77d23c4\"},\"headline\":\"Risques particuliers lors de la r\u00e9novation (7\\\/8)\",\"datePublished\":\"2020-10-21T06:03:00+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/blog.proclima.com\\\/suisse\\\/2020\\\/10\\\/21\\\/risques-particuliers-lors-de-la-renovation-7-8\\\/\"},\"wordCount\":477,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/blog.proclima.com\\\/suisse\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/blog.proclima.com\\\/suisse\\\/2020\\\/10\\\/21\\\/risques-particuliers-lors-de-la-renovation-7-8\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/blog.proclima.com\\\/suisse\\\/files\\\/2020\\\/07\\\/sprueh-dichtung-aerosana-visconn.jpg\",\"keywords\":[\"colles\",\"constructions anciennes\",\"enveloppe du b\u00e2ti\",\"\u00e9tanch\u00e9it\u00e9 \u00e0 l\u2019air\",\"frein-vapeur\",\"installation \u00e9lectrique\",\"passages\",\"points singuliers de raccords\",\"raccord aux \u00e9l\u00e9ments de construction\",\"raccord \u00e9tanche \u00e0 l\u2019air\",\"r\u00e9novation\",\"solutions pour points singuliers\"],\"articleSection\":[\"l\u2019\u00e9tanch\u00e9it\u00e9 \u00e0 l\u2019air\",\"pro clima\"],\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/blog.proclima.com\\\/suisse\\\/2020\\\/10\\\/21\\\/risques-particuliers-lors-de-la-renovation-7-8\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/blog.proclima.com\\\/suisse\\\/2020\\\/10\\\/21\\\/risques-particuliers-lors-de-la-renovation-7-8\\\/\",\"url\":\"https:\\\/\\\/blog.proclima.com\\\/suisse\\\/2020\\\/10\\\/21\\\/risques-particuliers-lors-de-la-renovation-7-8\\\/\",\"name\":\"Risques particuliers lors de la r\u00e9novation (7\\\/8) - blog pro clima Suisse\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/blog.proclima.com\\\/suisse\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/blog.proclima.com\\\/suisse\\\/2020\\\/10\\\/21\\\/risques-particuliers-lors-de-la-renovation-7-8\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/blog.proclima.com\\\/suisse\\\/2020\\\/10\\\/21\\\/risques-particuliers-lors-de-la-renovation-7-8\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/blog.proclima.com\\\/suisse\\\/files\\\/2020\\\/07\\\/sprueh-dichtung-aerosana-visconn.jpg\",\"datePublished\":\"2020-10-21T06:03:00+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/blog.proclima.com\\\/suisse\\\/2020\\\/10\\\/21\\\/risques-particuliers-lors-de-la-renovation-7-8\\\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/blog.proclima.com\\\/suisse\\\/2020\\\/10\\\/21\\\/risques-particuliers-lors-de-la-renovation-7-8\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/blog.proclima.com\\\/suisse\\\/2020\\\/10\\\/21\\\/risques-particuliers-lors-de-la-renovation-7-8\\\/#primaryimage\",\"url\":\"https:\\\/\\\/blog.proclima.com\\\/suisse\\\/files\\\/2020\\\/07\\\/sprueh-dichtung-aerosana-visconn.jpg\",\"contentUrl\":\"https:\\\/\\\/blog.proclima.com\\\/suisse\\\/files\\\/2020\\\/07\\\/sprueh-dichtung-aerosana-visconn.jpg\",\"width\":633,\"height\":355,\"caption\":\"Les supports rugueux ou poussi\u00e9reux peuvent \u00eatre pr\u00e9par\u00e9s avec AEROSANA VISCONN pour le collage ult\u00e9rieur des rubans adh\u00e9sifs pro clima. Pour cela, appliquer une couche couvrante de film pulv\u00e9ris\u00e9.\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/blog.proclima.com\\\/suisse\\\/2020\\\/10\\\/21\\\/risques-particuliers-lors-de-la-renovation-7-8\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Start\",\"item\":\"https:\\\/\\\/blog.proclima.com\\\/suisse\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Risques particuliers lors de la r\u00e9novation (7\\\/8)\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/blog.proclima.com\\\/suisse\\\/#website\",\"url\":\"https:\\\/\\\/blog.proclima.com\\\/suisse\\\/\",\"name\":\"blog pro clima Suisse\",\"description\":\"Des solutions fiables pour l\u2019\u00e9tanch\u00e9it\u00e9 du b\u00e2timent\",\"publisher\":{\"@id\":\"https:\\\/\\\/blog.proclima.com\\\/suisse\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/blog.proclima.com\\\/suisse\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/blog.proclima.com\\\/suisse\\\/#organization\",\"name\":\"blog pro clima Suisse\",\"url\":\"https:\\\/\\\/blog.proclima.com\\\/suisse\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/blog.proclima.com\\\/suisse\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/blog.proclima.com\\\/suisse\\\/files\\\/2025\\\/12\\\/logo_proclima_quadrat.png\",\"contentUrl\":\"https:\\\/\\\/blog.proclima.com\\\/suisse\\\/files\\\/2025\\\/12\\\/logo_proclima_quadrat.png\",\"width\":1200,\"height\":1200,\"caption\":\"blog pro clima Suisse\"},\"image\":{\"@id\":\"https:\\\/\\\/blog.proclima.com\\\/suisse\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/blog.proclima.com\\\/suisse\\\/#\\\/schema\\\/person\\\/867d432d923c4986caa239ecb77d23c4\",\"name\":\"Nils Braune\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/f258fd7697129815be29b291db5a9f8280d404bd5bc56d16f006d64d8437c89f?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/f258fd7697129815be29b291db5a9f8280d404bd5bc56d16f006d64d8437c89f?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/f258fd7697129815be29b291db5a9f8280d404bd5bc56d16f006d64d8437c89f?s=96&d=mm&r=g\",\"caption\":\"Nils Braune\"},\"description\":\"Nils Braune ist Journalist, Kameramann und TV-Redakteur. Teilnehmer*innen der Kombischulungen Dach-Praxis und Schnittstelle Baustelle kennen ihn, weil er dort die Live-\u00dcbertragungen und Aufzeichnungen unterst\u00fctzt. Bei pro clima Online-Seminaren ist er als Kameramann anzutreffen. Zudem supportet er die pro clima Redaktion (Blogs, proclima.tv und Bauradio). Nils Braune is a journalist, cameraman and TV producer. Participants in our combined training course on roofing practice and the interface with building sites will know him as he provides support with live broadcasts and recording. He is also familiar as a cameraman for pro clima online seminars. In addition, he provides support for pro clima\u2019s content editors (blogs, proclima.tv and \u2018Bauradio\u2019).\",\"url\":\"https:\\\/\\\/blog.proclima.com\\\/suisse\\\/author\\\/proclimaredaktion\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Risques particuliers lors de la r\u00e9novation (7\/8) - blog pro clima Suisse","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/blog.proclima.com\/suisse\/2020\/10\/21\/risques-particuliers-lors-de-la-renovation-7-8\/","og_locale":"fr_FR","og_type":"article","og_title":"Risques particuliers lors de la r\u00e9novation (7\/8) - blog pro clima Suisse","og_description":"R\u00e9alisation intelligente et efficace des raccords (7\/8) \u2013 Risques particuliers lors de la r\u00e9novation Suite de la section 6: Un probl\u00e8me des fen\u00eatres de toiture ...","og_url":"https:\/\/blog.proclima.com\/suisse\/2020\/10\/21\/risques-particuliers-lors-de-la-renovation-7-8\/","og_site_name":"blog pro clima Suisse","article_published_time":"2020-10-21T06:03:00+00:00","og_image":[{"width":633,"height":355,"url":"https:\/\/blog.proclima.com\/suisse\/files\/2020\/07\/sprueh-dichtung-aerosana-visconn.jpg","type":"image\/jpeg"}],"author":"Nils Braune","twitter_card":"summary_large_image","twitter_misc":{"\u00c9crit par":"Nils Braune","Dur\u00e9e de lecture estim\u00e9e":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/blog.proclima.com\/suisse\/2020\/10\/21\/risques-particuliers-lors-de-la-renovation-7-8\/#article","isPartOf":{"@id":"https:\/\/blog.proclima.com\/suisse\/2020\/10\/21\/risques-particuliers-lors-de-la-renovation-7-8\/"},"author":{"name":"Nils Braune","@id":"https:\/\/blog.proclima.com\/suisse\/#\/schema\/person\/867d432d923c4986caa239ecb77d23c4"},"headline":"Risques particuliers lors de la r\u00e9novation (7\/8)","datePublished":"2020-10-21T06:03:00+00:00","mainEntityOfPage":{"@id":"https:\/\/blog.proclima.com\/suisse\/2020\/10\/21\/risques-particuliers-lors-de-la-renovation-7-8\/"},"wordCount":477,"commentCount":0,"publisher":{"@id":"https:\/\/blog.proclima.com\/suisse\/#organization"},"image":{"@id":"https:\/\/blog.proclima.com\/suisse\/2020\/10\/21\/risques-particuliers-lors-de-la-renovation-7-8\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.proclima.com\/suisse\/files\/2020\/07\/sprueh-dichtung-aerosana-visconn.jpg","keywords":["colles","constructions anciennes","enveloppe du b\u00e2ti","\u00e9tanch\u00e9it\u00e9 \u00e0 l\u2019air","frein-vapeur","installation \u00e9lectrique","passages","points singuliers de raccords","raccord aux \u00e9l\u00e9ments de construction","raccord \u00e9tanche \u00e0 l\u2019air","r\u00e9novation","solutions pour points singuliers"],"articleSection":["l\u2019\u00e9tanch\u00e9it\u00e9 \u00e0 l\u2019air","pro clima"],"inLanguage":"fr-FR","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/blog.proclima.com\/suisse\/2020\/10\/21\/risques-particuliers-lors-de-la-renovation-7-8\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/blog.proclima.com\/suisse\/2020\/10\/21\/risques-particuliers-lors-de-la-renovation-7-8\/","url":"https:\/\/blog.proclima.com\/suisse\/2020\/10\/21\/risques-particuliers-lors-de-la-renovation-7-8\/","name":"Risques particuliers lors de la r\u00e9novation (7\/8) - blog pro clima Suisse","isPartOf":{"@id":"https:\/\/blog.proclima.com\/suisse\/#website"},"primaryImageOfPage":{"@id":"https:\/\/blog.proclima.com\/suisse\/2020\/10\/21\/risques-particuliers-lors-de-la-renovation-7-8\/#primaryimage"},"image":{"@id":"https:\/\/blog.proclima.com\/suisse\/2020\/10\/21\/risques-particuliers-lors-de-la-renovation-7-8\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.proclima.com\/suisse\/files\/2020\/07\/sprueh-dichtung-aerosana-visconn.jpg","datePublished":"2020-10-21T06:03:00+00:00","breadcrumb":{"@id":"https:\/\/blog.proclima.com\/suisse\/2020\/10\/21\/risques-particuliers-lors-de-la-renovation-7-8\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/blog.proclima.com\/suisse\/2020\/10\/21\/risques-particuliers-lors-de-la-renovation-7-8\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/blog.proclima.com\/suisse\/2020\/10\/21\/risques-particuliers-lors-de-la-renovation-7-8\/#primaryimage","url":"https:\/\/blog.proclima.com\/suisse\/files\/2020\/07\/sprueh-dichtung-aerosana-visconn.jpg","contentUrl":"https:\/\/blog.proclima.com\/suisse\/files\/2020\/07\/sprueh-dichtung-aerosana-visconn.jpg","width":633,"height":355,"caption":"Les supports rugueux ou poussi\u00e9reux peuvent \u00eatre pr\u00e9par\u00e9s avec AEROSANA VISCONN pour le collage ult\u00e9rieur des rubans adh\u00e9sifs pro clima. Pour cela, appliquer une couche couvrante de film pulv\u00e9ris\u00e9."},{"@type":"BreadcrumbList","@id":"https:\/\/blog.proclima.com\/suisse\/2020\/10\/21\/risques-particuliers-lors-de-la-renovation-7-8\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Start","item":"https:\/\/blog.proclima.com\/suisse\/"},{"@type":"ListItem","position":2,"name":"Risques particuliers lors de la r\u00e9novation (7\/8)"}]},{"@type":"WebSite","@id":"https:\/\/blog.proclima.com\/suisse\/#website","url":"https:\/\/blog.proclima.com\/suisse\/","name":"blog pro clima Suisse","description":"Des solutions fiables pour l\u2019\u00e9tanch\u00e9it\u00e9 du b\u00e2timent","publisher":{"@id":"https:\/\/blog.proclima.com\/suisse\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/blog.proclima.com\/suisse\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/blog.proclima.com\/suisse\/#organization","name":"blog pro clima Suisse","url":"https:\/\/blog.proclima.com\/suisse\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/blog.proclima.com\/suisse\/#\/schema\/logo\/image\/","url":"https:\/\/blog.proclima.com\/suisse\/files\/2025\/12\/logo_proclima_quadrat.png","contentUrl":"https:\/\/blog.proclima.com\/suisse\/files\/2025\/12\/logo_proclima_quadrat.png","width":1200,"height":1200,"caption":"blog pro clima Suisse"},"image":{"@id":"https:\/\/blog.proclima.com\/suisse\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/blog.proclima.com\/suisse\/#\/schema\/person\/867d432d923c4986caa239ecb77d23c4","name":"Nils Braune","image":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/secure.gravatar.com\/avatar\/f258fd7697129815be29b291db5a9f8280d404bd5bc56d16f006d64d8437c89f?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/f258fd7697129815be29b291db5a9f8280d404bd5bc56d16f006d64d8437c89f?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/f258fd7697129815be29b291db5a9f8280d404bd5bc56d16f006d64d8437c89f?s=96&d=mm&r=g","caption":"Nils Braune"},"description":"Nils Braune ist Journalist, Kameramann und TV-Redakteur. Teilnehmer*innen der Kombischulungen Dach-Praxis und Schnittstelle Baustelle kennen ihn, weil er dort die Live-\u00dcbertragungen und Aufzeichnungen unterst\u00fctzt. Bei pro clima Online-Seminaren ist er als Kameramann anzutreffen. Zudem supportet er die pro clima Redaktion (Blogs, proclima.tv und Bauradio). Nils Braune is a journalist, cameraman and TV producer. Participants in our combined training course on roofing practice and the interface with building sites will know him as he provides support with live broadcasts and recording. He is also familiar as a cameraman for pro clima online seminars. In addition, he provides support for pro clima\u2019s content editors (blogs, proclima.tv and \u2018Bauradio\u2019).","url":"https:\/\/blog.proclima.com\/suisse\/author\/proclimaredaktion\/"}]}},"_links":{"self":[{"href":"https:\/\/blog.proclima.com\/suisse\/wp-json\/wp\/v2\/posts\/186","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blog.proclima.com\/suisse\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blog.proclima.com\/suisse\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blog.proclima.com\/suisse\/wp-json\/wp\/v2\/users\/40"}],"replies":[{"embeddable":true,"href":"https:\/\/blog.proclima.com\/suisse\/wp-json\/wp\/v2\/comments?post=186"}],"version-history":[{"count":7,"href":"https:\/\/blog.proclima.com\/suisse\/wp-json\/wp\/v2\/posts\/186\/revisions"}],"predecessor-version":[{"id":233,"href":"https:\/\/blog.proclima.com\/suisse\/wp-json\/wp\/v2\/posts\/186\/revisions\/233"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/blog.proclima.com\/suisse\/wp-json\/wp\/v2\/media\/157"}],"wp:attachment":[{"href":"https:\/\/blog.proclima.com\/suisse\/wp-json\/wp\/v2\/media?parent=186"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blog.proclima.com\/suisse\/wp-json\/wp\/v2\/categories?post=186"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blog.proclima.com\/suisse\/wp-json\/wp\/v2\/tags?post=186"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}