{"id":401,"date":"2020-07-08T20:37:00","date_gmt":"2020-07-08T20:37:00","guid":{"rendered":"https:\/\/blog.proclima.com\/int\/?p=401"},"modified":"2025-10-16T06:02:15","modified_gmt":"2025-10-16T06:02:15","slug":"6-problem-with-skylights-adhesive-bonds-at-corners","status":"publish","type":"post","link":"https:\/\/blog.proclima.com\/int\/2020\/07\/08\/6-problem-with-skylights-adhesive-bonds-at-corners\/","title":{"rendered":"Intelligent, effective solutions for joints&nbsp;(6\/8) \u2013 Problem with skylights: adhesive bonds at corners"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\"><em><em>Continuation of Part<\/em> 5: <a href=\"https:\/\/blog.proclima.com\/int\/2020\/07\/01\/5-care-required-at-the-corners-of-plastic-windows\/\">Care required at the corners of plastic windows:<\/a><\/em><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A challenging corner joint arises when installing skylights. The membrane is guided up to the surrounding window profile all around the window and has to be stuck there in a reliable, sealed manner, even at the corners. Particular care must be taken at the corners. An experienced tradesperson can achieve an uninterrupted airtight seal here using prefolded adhesive tapes. Prefabricated corners, which may be adapted for the width of the surrounding window profile that is present if necessary, are a reliable alternative.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/blog.proclima.com\/de\/files\/2020\/04\/dachfenster-sicher-anschlie\u00dfen-1.jpg\" alt=\"\" class=\"wp-image-8626\" \/><figcaption class=\"wp-element-caption\">The corners of skylights always show up first in blower door tests. It is important to start by sealing the corner and then to seal the surrounding window profile all around the window. This challenge can be solved by installation tradespeople by folding adhesive tape to create a corner element.<\/figcaption><\/figure>\n\n\n\n<p class=\"has-light-gray-background-color has-background wp-block-paragraph\">This series of articles summarises typical, challenging joint situations and shows how technicians can find practical solutions for these challenges. It also provides an overview of the detail features for which prefabricated solutions are available that allow tradespeople to achieve airtightness in a quick, easy and reliable manner.<\/p>\n\n\n\n<!--more-->\n\n\n\n<figure class=\"wp-block-gallery has-nested-images columns-default is-cropped wp-block-gallery-1 is-layout-flex wp-block-gallery-is-layout-flex\">\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/blog.proclima.com\/de\/files\/2020\/04\/dachfenster-sicher-anschlie\u00dfen-2.jpg\"><img decoding=\"async\" data-id=\"8627\" src=\"https:\/\/blog.proclima.com\/de\/files\/2020\/04\/dachfenster-sicher-anschlie\u00dfen-2.jpg\" alt=\"\" class=\"wp-image-8627\" \/><\/a><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/blog.proclima.com\/de\/files\/2020\/04\/dachfenster-sicher-anschlie\u00dfen-3.jpg\"><img decoding=\"async\" data-id=\"8628\" src=\"https:\/\/blog.proclima.com\/de\/files\/2020\/04\/dachfenster-sicher-anschlie\u00dfen-3.jpg\" alt=\"\" class=\"wp-image-8628\" \/><\/a><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/blog.proclima.com\/de\/files\/2020\/04\/dachfenster-sicher-anschlie\u00dfen-4.jpg\"><img decoding=\"async\" data-id=\"8629\" src=\"https:\/\/blog.proclima.com\/de\/files\/2020\/04\/dachfenster-sicher-anschlie\u00dfen-4.jpg\" alt=\"\" class=\"wp-image-8629\" \/><\/a><\/figure>\n<figcaption class=\"blocks-gallery-caption wp-element-caption\">This is how adhesive tape can be formed into a prefolded corner element.<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-gallery has-nested-images columns-default is-cropped wp-block-gallery-2 is-layout-flex wp-block-gallery-is-layout-flex\">\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/blog.proclima.com\/de\/files\/2020\/04\/dachfenster-sicher-anschlie\u00dfen-vorgefertigt-1.jpg\"><img decoding=\"async\" data-id=\"8631\" src=\"https:\/\/blog.proclima.com\/de\/files\/2020\/04\/dachfenster-sicher-anschlie\u00dfen-vorgefertigt-1.jpg\" alt=\"\" class=\"wp-image-8631\" \/><\/a><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/blog.proclima.com\/de\/files\/2020\/04\/dachfenster-sicher-anschlie\u00dfen-vorgefertigt-2.jpg\"><img decoding=\"async\" data-id=\"8632\" src=\"https:\/\/blog.proclima.com\/de\/files\/2020\/04\/dachfenster-sicher-anschlie\u00dfen-vorgefertigt-2.jpg\" alt=\"\" class=\"wp-image-8632\" \/><\/a><\/figure>\n<figcaption class=\"blocks-gallery-caption wp-element-caption\">Quick, prefabricated solution for corners on skylights: self-adhesive, three-dimensional shaped element for interior corners.<\/figcaption><\/figure>\n\n\n\n<div class=\"wp-block-group has-light-gray-background-color has-background\"><div class=\"wp-block-group__inner-container is-layout-flow wp-block-group-is-layout-flow\">\n<h2 class=\"wp-block-heading\">This Series was written by Jens L\u00fcder Herms and Holger Merkel<\/h2>\n\n\n\n<div class=\"wp-block-media-text alignwide\" style=\"grid-template-columns:22% auto\"><figure class=\"wp-block-media-text__media\"><img decoding=\"async\" src=\"https:\/\/blog.proclima.com\/de\/files\/2020\/04\/Jens-Lueder-Herms.jpg\" alt=\"Jens L\u00fcder Herms, Zimmerer &amp; Diplom-Ingenieur (FH), Exportmanager und Anwendungstechniker\" class=\"wp-image-8539 size-full\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<p class=\"wp-block-paragraph\">Jens L\u00fcder Herms, carpenter and graduate engineer, Export Manager and Application Technology specialist, pro clima Research and Development,, <a href=\"https:\/\/www.proclima.de\">www.proclima.de<\/a>. He provides insights into his work on <a href=\"https:\/\/twitter.com\/luederHerms\">Twitter<\/a> and <a href=\"https:\/\/www.instagram.com\/jens.lueder.herms\/\">Instagram<\/a>.<\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-media-text alignwide has-media-on-the-right\" style=\"grid-template-columns:auto 22%\"><div class=\"wp-block-media-text__content\">\n<p class=\"wp-block-paragraph\">Holger Merkel, provider of blower door measurement services, speaker at the pro clima <a href=\"https:\/\/kaenguru.me\/\">Knowledge Lab<\/a> and instructor for certification courses.. He has documented examples of leaks in his most recent project <a href=\"https:\/\/www.zieht-wie-hechtsupp.de\/\">www.zieht-wie-hechtsupp.de<\/a>. He also publishes specialist articles on issues such as blower door tests on <a href=\"https:\/\/www.airtight-junkies.de\/\">www.airtight-junkies.de<\/a>.<\/p>\n<\/div><figure class=\"wp-block-media-text__media\"><img decoding=\"async\" src=\"https:\/\/blog.proclima.com\/de\/files\/2020\/04\/Holger-Merkel.jpg\" alt=\"Holger Merkel, Blower-Door-Messdienstleister, Referent der pro clima Wissenwerkstatt und Leiter von Zertifizierungskursen\" class=\"wp-image-8540 size-full\" \/><\/figure><\/div>\n<\/div><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Continuation of Part 5: Care required at the corners of plastic windows: A challenging corner joint arises when installing skylights. The membrane is guided up <a href=\"https:\/\/blog.proclima.com\/int\/2020\/07\/08\/6-problem-with-skylights-adhesive-bonds-at-corners\/\" rel=\"bookmark\">&#8230;<\/a><\/p>\n","protected":false},"author":37,"featured_media":418,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[12,115,142,143],"class_list":["post-401","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-pro-clima","tag-airtightness","tag-airtightness-sealing","tag-corner","tag-skylights"],"canto_acf_fields":"","_links":{"self":[{"href":"https:\/\/blog.proclima.com\/int\/wp-json\/wp\/v2\/posts\/401","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blog.proclima.com\/int\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blog.proclima.com\/int\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blog.proclima.com\/int\/wp-json\/wp\/v2\/users\/37"}],"replies":[{"embeddable":true,"href":"https:\/\/blog.proclima.com\/int\/wp-json\/wp\/v2\/comments?post=401"}],"version-history":[{"count":6,"href":"https:\/\/blog.proclima.com\/int\/wp-json\/wp\/v2\/posts\/401\/revisions"}],"predecessor-version":[{"id":534,"href":"https:\/\/blog.proclima.com\/int\/wp-json\/wp\/v2\/posts\/401\/revisions\/534"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/blog.proclima.com\/int\/wp-json\/wp\/v2\/media\/418"}],"wp:attachment":[{"href":"https:\/\/blog.proclima.com\/int\/wp-json\/wp\/v2\/media?parent=401"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blog.proclima.com\/int\/wp-json\/wp\/v2\/categories?post=401"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blog.proclima.com\/int\/wp-json\/wp\/v2\/tags?post=401"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}