{"id":325,"date":"2014-09-03T06:00:16","date_gmt":"2014-09-03T04:00:16","guid":{"rendered":"http:\/\/blog.proclima.com\/fr\/?p=325"},"modified":"2014-09-09T10:31:53","modified_gmt":"2014-09-09T08:31:53","slug":"serie-renovation-interieure-2","status":"publish","type":"post","link":"https:\/\/blog.proclima.com\/fr\/2014\/09\/serie-renovation-interieure-2\/","title":{"rendered":"S\u00e9rie isolation int\u00e9rieure &#8211; partie N\u00b02: Les zones critiques dans l&rsquo;isolation par l&rsquo;int\u00e9rieur- o\u00f9 et pourquoi faut-il \u00eatre prudent?"},"content":{"rendered":"<figure id=\"attachment_362\" aria-describedby=\"caption-attachment-362\" style=\"width: 1024px\" class=\"wp-caption aligncenter\"><a href=\"http:\/\/blog.proclima.com\/fr\/files\/2014\/09\/Bild4-1024x768.jpg\"><img loading=\"lazy\" decoding=\"async\" data-size=\"1024x768\" class=\"wp-image-362 size-full\" src=\"http:\/\/blog.proclima.com\/fr\/files\/2014\/09\/Bild4-1024x768.jpg\" alt=\"Bild4-1024x768\" width=\"1024\" height=\"768\" srcset=\"https:\/\/blog.proclima.com\/fr\/files\/2014\/09\/Bild4-1024x768.jpg 1024w, https:\/\/blog.proclima.com\/fr\/files\/2014\/09\/Bild4-1024x768-300x225.jpg 300w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><figcaption id=\"caption-attachment-362\" class=\"wp-caption-text\">Formation des moissisures dans une isolation int\u00e9rieure<\/figcaption><\/figure>\n<p>&nbsp;<\/p>\n<p>L&rsquo;\u00e9tanch\u00e9it\u00e9 \u00e0 l&rsquo;air est un point crucial dans les constructions neuves, mais \u00e9galement dans<br \/>\nles r\u00e9novations, notamment pour le label BBC-r\u00e9novation. Il existe diff\u00e9rents produits permettant d\u2019obtenir une construction \u00e9tanche \u00e0 l&rsquo;air. Cela peut \u00eatre un enduit int\u00e9rieur, une membrane, des panneaux (plaques de pl\u00e2tre \u00e0 parement cartonn\u00e9, OSB)\u2026<\/p>\n<p>N\u00e9anmoins les caract\u00e9ristiques de ces diff\u00e9rents produits sont tr\u00e8s variables et il est n\u00e9cessaire lors de la conception et la r\u00e9alisation de choisir quel syst\u00e8me sera utilis\u00e9 \u00e0 quel endroit de la construction et surtout dans quel but. Le terme \u00ab \u00e9tanch\u00e9it\u00e9 \u00e0 l&rsquo;air \u00bb est dans la plupart des pays europ\u00e9ens (Allemagne, Suisse, Belgique, Autriche) d\u00e9fini comme une couche install\u00e9e c\u00f4t\u00e9 int\u00e9rieur de l&rsquo;isolant (c\u00f4t\u00e9 chaud) qui apporte une r\u00e9sistance \u00e0 la diffusion de vapeur d&rsquo;eau (frein-vapeur et pare-vapeur).<\/p>\n<p><!--more--><br \/>\nCe n&rsquo;est souvent pas le cas en France, o\u00f9 il existe des produits vendus par les fabricants<br \/>\ncomme produits d&rsquo;\u00e9tanch\u00e9it\u00e9 \u00e0 l&rsquo;air qui sont tr\u00e8s ouverts \u00e0 la diffusion de vapeur d&rsquo;eau.<br \/>\nCes produits se posent directement contre le mur existant, donc c\u00f4t\u00e9 froid de la couche<br \/>\nd&rsquo;isolation, ce qui augmente le risque de condensation entre le mur et l\u2019isolant.<br \/>\nSi l&rsquo;isolation est r\u00e9alis\u00e9e \u00e0 l&rsquo;aide de panneaux composites rigides, selon les prescriptions<br \/>\ndu DTU 25.42, et que l&rsquo;\u00e9tanch\u00e9it\u00e9 est assur\u00e9e par un enduit ou une membrane pos\u00e9 sur<br \/>\nle mur, il y a toujours un risque de circulation d&rsquo;air qui, parvenu au dos de l\u2019isolant, peut se<br \/>\nrefroidir progressivement et atteindre le point de ros\u00e9e.<br \/>\nPour \u00e9viter ce probl\u00e8me, la meilleure solution est de placer la membrane frein-vapeur\/<br \/>\npare-vapeur c\u00f4t\u00e9 chaud de l&rsquo;isolant et de le prot\u00e9ger ainsi de l\u2019air chaud et humide provenant de la pi\u00e8ce occup\u00e9e.<br \/>\nLe point faible dans une telle configuration de mur (isolation int\u00e9rieure rapport\u00e9e)<br \/>\nr\u00e9side aussi dans le pont thermique situ\u00e9 au niveau du plafond interm\u00e9diaire, zone difficile<br \/>\n\u00e0 isoler en r\u00e9novation. Il se traduit par des temp\u00e9ratures plus froides au niveau<br \/>\ndes solives que sur le mur isol\u00e9. La figure 8 montre ce qui se passe avec une temp\u00e9rature<br \/>\nint\u00e9rieure de 20 \u00b0C et une humidit\u00e9 relative de 50 %, le point de ros\u00e9e est atteint<br \/>\n\u00e0 une temp\u00e9rature de 9,3 \u00b0C. C&rsquo;est pourquoi l&rsquo;isotherme* de 10 \u00b0C est \u00e9galement connu<br \/>\nsous le nom \u00ab isotherme de condensation \u00bb et c&rsquo;est bien cette temp\u00e9rature, ou plut\u00f4t son<br \/>\nemplacement dans la construction, qui est \u00e0 analyser pour chaque projet de r\u00e9novation<br \/>\nen cas d\u2019isolation par l\u2019int\u00e9rieur. Si les temp\u00e9ratures superficielles diminuent comme le<br \/>\nmontre la figure 9, le risque d&rsquo;une formation de moisissure et de condensation augmente,<br \/>\ntout d&rsquo;abord dans les angles autour des solives ou aux coins d&rsquo;un mur de refend.<\/p>\n<p>Tous les articles de la s\u00e9rie:<\/p>\n<ul>\n<li>Introduction<br \/>\n<a href=\"http:\/\/blog.proclima.com\/fr\/2014\/09\/serie-renovation-interieure\/\" target=\"_blank\"><span id=\"sample-permalink\">http:\/\/blog.proclima.com\/fr\/2014\/09\/<span id=\"editable-post-name\" title=\"Permalien temporaire. Cliquez pour modifier cette section.\">serie-renovation-interieure<\/span>\/<\/span><\/a><\/li>\n<\/ul>\n<ul>\n<li>partie N\u00b01: Risques de l&rsquo;isolation par l&rsquo;int\u00e9rieur versus exigences pour obtenir des aides financi\u00e8res\u00a0\u00a0 <a href=\"http:\/\/blog.proclima.com\/fr\/2014\/09\/serie-renovation-interieure-1\" target=\"_blank\"><span id=\"sample-permalink\">http:\/\/blog.proclima.com\/fr\/2014\/09\/<span id=\"editable-post-name\" title=\"Permalien temporaire. Cliquez pour modifier cette section.\">serie-renovation-interieure-1<\/span><\/span><\/a><\/li>\n<\/ul>\n<ul>\n<li>partie N\u00b02: Les zones critiques dans l&rsquo;isolation par l&rsquo;int\u00e9rieur- o\u00f9 et pourquoi faut-il \u00eatre prudent?\u00a0\u00a0 <a href=\"http:\/\/blog.proclima.com\/fr\/2014\/09\/serie-renovation-interieure-2\/\" target=\"_blank\"><span id=\"sample-permalink\">http:\/\/blog.proclima.com\/fr\/2014\/09\/<span id=\"editable-post-name\" title=\"Permalien temporaire. Cliquez pour modifier cette section.\">serie-renovation-interieure-2<\/span>\/<\/span><\/a><\/li>\n<\/ul>\n<ul>\n<li>partie N\u00b03: Exemple de r\u00e9novation d\u00e9fectueuse: Quelles causes et quelles cons\u00e9quences pour l&rsquo;homme et la sant\u00e9?\u00a0\u00a0 <a href=\"http:\/\/blog.proclima.com\/fr\/2014\/09\/serie-renovation-interieure-3\" target=\"_blank\"><span id=\"sample-permalink\">http:\/\/blog.proclima.com\/fr\/2014\/09\/<span id=\"editable-post-name\" title=\"Permalien temporaire. Cliquez pour modifier cette section.\">serie-renovation-interieure-3<\/span><\/span><\/a><\/li>\n<\/ul>\n<ul>\n<li>partie N\u00b04: La r\u00e9novation appropri\u00e9e du d\u00e9g\u00e2t au b\u00e2timent\u00a0 <a href=\"http:\/\/blog.proclima.com\/fr\/2014\/09\/serie-renovation-interieure-4\/\" target=\"_blank\"><span id=\"sample-permalink\">http:\/\/blog.proclima.com\/fr\/2014\/09\/<span id=\"editable-post-name\" title=\"Permalien temporaire. Cliquez pour modifier cette section.\">serie-renovation-interieure-4<\/span>\/<\/span><\/a><\/li>\n<\/ul>\n<ul>\n<li>\u00a0partie N\u00b05: R\u00e9sum\u00e9: Les moisissures sont dangereuses et la r\u00e9novation saine et sans d\u00e9g\u00e2t incontournable\u00a0\u00a0 <a href=\"http:\/\/blog.proclima.com\/fr\/2014\/09\/serie-renovation-interieure-5\/\" target=\"_blank\"><span id=\"sample-permalink\">http:\/\/blog.proclima.com\/fr\/2014\/09\/<span id=\"editable-post-name\" title=\"Permalien temporaire. Cliquez pour modifier cette section.\">serie-renovation-interieure-5<\/span>\/<\/span><\/a><\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>&nbsp; L&rsquo;\u00e9tanch\u00e9it\u00e9 \u00e0 l&rsquo;air est un point crucial dans les constructions neuves, mais \u00e9galement dans les r\u00e9novations, notamment pour le label BBC-r\u00e9novation. Il existe diff\u00e9rents <a href=\"https:\/\/blog.proclima.com\/fr\/2014\/09\/serie-renovation-interieure-2\/\" rel=\"bookmark\">&#8230;<\/a><\/p>\n","protected":false},"author":16,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[79,1],"tags":[80,16,77],"class_list":["post-325","post","type-post","status-publish","format-standard","hentry","category-article-pro","category-general","tag-isolation-interieure","tag-pro-clima","tag-serie"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.6 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>S\u00e9rie isolation int\u00e9rieure - partie N\u00b02: Les zones critiques dans l&#039;isolation par l&#039;int\u00e9rieur- o\u00f9 et pourquoi faut-il \u00eatre prudent? - pro clima Blog - france<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/blog.proclima.com\/fr\/2014\/09\/serie-renovation-interieure-2\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"S\u00e9rie isolation int\u00e9rieure - partie N\u00b02: Les zones critiques dans l&#039;isolation par l&#039;int\u00e9rieur- o\u00f9 et pourquoi faut-il \u00eatre prudent? - pro clima Blog - france\" \/>\n<meta property=\"og:description\" content=\"&nbsp; L&rsquo;\u00e9tanch\u00e9it\u00e9 \u00e0 l&rsquo;air est un point crucial dans les constructions neuves, mais \u00e9galement dans les r\u00e9novations, notamment pour le label BBC-r\u00e9novation. Il existe diff\u00e9rents ...\" \/>\n<meta property=\"og:url\" content=\"https:\/\/blog.proclima.com\/fr\/2014\/09\/serie-renovation-interieure-2\/\" \/>\n<meta property=\"og:site_name\" content=\"pro clima Blog - france\" \/>\n<meta property=\"article:published_time\" content=\"2014-09-03T04:00:16+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2014-09-09T08:31:53+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/blog.proclima.com\/fr\/files\/2014\/09\/Bild4-1024x768.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\" \/>\n\t<meta name=\"twitter:data1\" content=\"\" \/>\n\t<meta name=\"twitter:label2\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/blog.proclima.com\\\/fr\\\/2014\\\/09\\\/serie-renovation-interieure-2\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/blog.proclima.com\\\/fr\\\/2014\\\/09\\\/serie-renovation-interieure-2\\\/\"},\"author\":{\"name\":\"\",\"@id\":\"\"},\"headline\":\"S\u00e9rie isolation int\u00e9rieure &#8211; partie N\u00b02: Les zones critiques dans l&rsquo;isolation par l&rsquo;int\u00e9rieur- o\u00f9 et pourquoi faut-il \u00eatre prudent?\",\"datePublished\":\"2014-09-03T04:00:16+00:00\",\"dateModified\":\"2014-09-09T08:31:53+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/blog.proclima.com\\\/fr\\\/2014\\\/09\\\/serie-renovation-interieure-2\\\/\"},\"wordCount\":640,\"commentCount\":2,\"publisher\":{\"@id\":\"https:\\\/\\\/blog.proclima.com\\\/fr\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/blog.proclima.com\\\/fr\\\/2014\\\/09\\\/serie-renovation-interieure-2\\\/#primaryimage\"},\"thumbnailUrl\":\"http:\\\/\\\/blog.proclima.com\\\/fr\\\/files\\\/2014\\\/09\\\/Bild4-1024x768.jpg\",\"keywords\":[\"isolation int\u00e9rieure\",\"pro clima\",\"s\u00e9rie\"],\"articleSection\":[\"Connaissances techniques\",\"pro clima\"],\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/blog.proclima.com\\\/fr\\\/2014\\\/09\\\/serie-renovation-interieure-2\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/blog.proclima.com\\\/fr\\\/2014\\\/09\\\/serie-renovation-interieure-2\\\/\",\"url\":\"https:\\\/\\\/blog.proclima.com\\\/fr\\\/2014\\\/09\\\/serie-renovation-interieure-2\\\/\",\"name\":\"S\u00e9rie isolation int\u00e9rieure - partie N\u00b02: Les zones critiques dans l'isolation par l'int\u00e9rieur- o\u00f9 et pourquoi faut-il \u00eatre prudent? - pro clima Blog - france\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/blog.proclima.com\\\/fr\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/blog.proclima.com\\\/fr\\\/2014\\\/09\\\/serie-renovation-interieure-2\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/blog.proclima.com\\\/fr\\\/2014\\\/09\\\/serie-renovation-interieure-2\\\/#primaryimage\"},\"thumbnailUrl\":\"http:\\\/\\\/blog.proclima.com\\\/fr\\\/files\\\/2014\\\/09\\\/Bild4-1024x768.jpg\",\"datePublished\":\"2014-09-03T04:00:16+00:00\",\"dateModified\":\"2014-09-09T08:31:53+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/blog.proclima.com\\\/fr\\\/2014\\\/09\\\/serie-renovation-interieure-2\\\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/blog.proclima.com\\\/fr\\\/2014\\\/09\\\/serie-renovation-interieure-2\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/blog.proclima.com\\\/fr\\\/2014\\\/09\\\/serie-renovation-interieure-2\\\/#primaryimage\",\"url\":\"http:\\\/\\\/blog.proclima.com\\\/fr\\\/files\\\/2014\\\/09\\\/Bild4-1024x768.jpg\",\"contentUrl\":\"http:\\\/\\\/blog.proclima.com\\\/fr\\\/files\\\/2014\\\/09\\\/Bild4-1024x768.jpg\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/blog.proclima.com\\\/fr\\\/2014\\\/09\\\/serie-renovation-interieure-2\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Accueil\",\"item\":\"https:\\\/\\\/blog.proclima.com\\\/fr\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"S\u00e9rie isolation int\u00e9rieure &#8211; partie N\u00b02: Les zones critiques dans l&rsquo;isolation par l&rsquo;int\u00e9rieur- o\u00f9 et pourquoi faut-il \u00eatre prudent?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/blog.proclima.com\\\/fr\\\/#website\",\"url\":\"https:\\\/\\\/blog.proclima.com\\\/fr\\\/\",\"name\":\"pro clima Blog - france\",\"description\":\"pro clima Blog\",\"publisher\":{\"@id\":\"https:\\\/\\\/blog.proclima.com\\\/fr\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/blog.proclima.com\\\/fr\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/blog.proclima.com\\\/fr\\\/#organization\",\"name\":\"pro clima Blog - france\",\"url\":\"https:\\\/\\\/blog.proclima.com\\\/fr\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/blog.proclima.com\\\/fr\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/blog.proclima.com\\\/fr\\\/files\\\/2025\\\/12\\\/logo_proclima_quadrat.png\",\"contentUrl\":\"https:\\\/\\\/blog.proclima.com\\\/fr\\\/files\\\/2025\\\/12\\\/logo_proclima_quadrat.png\",\"width\":1200,\"height\":1200,\"caption\":\"pro clima Blog - france\"},\"image\":{\"@id\":\"https:\\\/\\\/blog.proclima.com\\\/fr\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"\",\"url\":\"https:\\\/\\\/blog.proclima.com\\\/fr\\\/author\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"S\u00e9rie isolation int\u00e9rieure - partie N\u00b02: Les zones critiques dans l'isolation par l'int\u00e9rieur- o\u00f9 et pourquoi faut-il \u00eatre prudent? - pro clima Blog - france","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/blog.proclima.com\/fr\/2014\/09\/serie-renovation-interieure-2\/","og_locale":"fr_FR","og_type":"article","og_title":"S\u00e9rie isolation int\u00e9rieure - partie N\u00b02: Les zones critiques dans l'isolation par l'int\u00e9rieur- o\u00f9 et pourquoi faut-il \u00eatre prudent? - pro clima Blog - france","og_description":"&nbsp; L&rsquo;\u00e9tanch\u00e9it\u00e9 \u00e0 l&rsquo;air est un point crucial dans les constructions neuves, mais \u00e9galement dans les r\u00e9novations, notamment pour le label BBC-r\u00e9novation. Il existe diff\u00e9rents ...","og_url":"https:\/\/blog.proclima.com\/fr\/2014\/09\/serie-renovation-interieure-2\/","og_site_name":"pro clima Blog - france","article_published_time":"2014-09-03T04:00:16+00:00","article_modified_time":"2014-09-09T08:31:53+00:00","og_image":[{"url":"http:\/\/blog.proclima.com\/fr\/files\/2014\/09\/Bild4-1024x768.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"\u00c9crit par":"","Dur\u00e9e de lecture estim\u00e9e":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/blog.proclima.com\/fr\/2014\/09\/serie-renovation-interieure-2\/#article","isPartOf":{"@id":"https:\/\/blog.proclima.com\/fr\/2014\/09\/serie-renovation-interieure-2\/"},"author":{"name":"","@id":""},"headline":"S\u00e9rie isolation int\u00e9rieure &#8211; partie N\u00b02: Les zones critiques dans l&rsquo;isolation par l&rsquo;int\u00e9rieur- o\u00f9 et pourquoi faut-il \u00eatre prudent?","datePublished":"2014-09-03T04:00:16+00:00","dateModified":"2014-09-09T08:31:53+00:00","mainEntityOfPage":{"@id":"https:\/\/blog.proclima.com\/fr\/2014\/09\/serie-renovation-interieure-2\/"},"wordCount":640,"commentCount":2,"publisher":{"@id":"https:\/\/blog.proclima.com\/fr\/#organization"},"image":{"@id":"https:\/\/blog.proclima.com\/fr\/2014\/09\/serie-renovation-interieure-2\/#primaryimage"},"thumbnailUrl":"http:\/\/blog.proclima.com\/fr\/files\/2014\/09\/Bild4-1024x768.jpg","keywords":["isolation int\u00e9rieure","pro clima","s\u00e9rie"],"articleSection":["Connaissances techniques","pro clima"],"inLanguage":"fr-FR","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/blog.proclima.com\/fr\/2014\/09\/serie-renovation-interieure-2\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/blog.proclima.com\/fr\/2014\/09\/serie-renovation-interieure-2\/","url":"https:\/\/blog.proclima.com\/fr\/2014\/09\/serie-renovation-interieure-2\/","name":"S\u00e9rie isolation int\u00e9rieure - partie N\u00b02: Les zones critiques dans l'isolation par l'int\u00e9rieur- o\u00f9 et pourquoi faut-il \u00eatre prudent? - pro clima Blog - france","isPartOf":{"@id":"https:\/\/blog.proclima.com\/fr\/#website"},"primaryImageOfPage":{"@id":"https:\/\/blog.proclima.com\/fr\/2014\/09\/serie-renovation-interieure-2\/#primaryimage"},"image":{"@id":"https:\/\/blog.proclima.com\/fr\/2014\/09\/serie-renovation-interieure-2\/#primaryimage"},"thumbnailUrl":"http:\/\/blog.proclima.com\/fr\/files\/2014\/09\/Bild4-1024x768.jpg","datePublished":"2014-09-03T04:00:16+00:00","dateModified":"2014-09-09T08:31:53+00:00","breadcrumb":{"@id":"https:\/\/blog.proclima.com\/fr\/2014\/09\/serie-renovation-interieure-2\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/blog.proclima.com\/fr\/2014\/09\/serie-renovation-interieure-2\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/blog.proclima.com\/fr\/2014\/09\/serie-renovation-interieure-2\/#primaryimage","url":"http:\/\/blog.proclima.com\/fr\/files\/2014\/09\/Bild4-1024x768.jpg","contentUrl":"http:\/\/blog.proclima.com\/fr\/files\/2014\/09\/Bild4-1024x768.jpg"},{"@type":"BreadcrumbList","@id":"https:\/\/blog.proclima.com\/fr\/2014\/09\/serie-renovation-interieure-2\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Accueil","item":"https:\/\/blog.proclima.com\/fr\/"},{"@type":"ListItem","position":2,"name":"S\u00e9rie isolation int\u00e9rieure &#8211; partie N\u00b02: Les zones critiques dans l&rsquo;isolation par l&rsquo;int\u00e9rieur- o\u00f9 et pourquoi faut-il \u00eatre prudent?"}]},{"@type":"WebSite","@id":"https:\/\/blog.proclima.com\/fr\/#website","url":"https:\/\/blog.proclima.com\/fr\/","name":"pro clima Blog - france","description":"pro clima Blog","publisher":{"@id":"https:\/\/blog.proclima.com\/fr\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/blog.proclima.com\/fr\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/blog.proclima.com\/fr\/#organization","name":"pro clima Blog - france","url":"https:\/\/blog.proclima.com\/fr\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/blog.proclima.com\/fr\/#\/schema\/logo\/image\/","url":"https:\/\/blog.proclima.com\/fr\/files\/2025\/12\/logo_proclima_quadrat.png","contentUrl":"https:\/\/blog.proclima.com\/fr\/files\/2025\/12\/logo_proclima_quadrat.png","width":1200,"height":1200,"caption":"pro clima Blog - france"},"image":{"@id":"https:\/\/blog.proclima.com\/fr\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"","url":"https:\/\/blog.proclima.com\/fr\/author\/"}]}},"_links":{"self":[{"href":"https:\/\/blog.proclima.com\/fr\/wp-json\/wp\/v2\/posts\/325","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blog.proclima.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blog.proclima.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blog.proclima.com\/fr\/wp-json\/wp\/v2\/users\/16"}],"replies":[{"embeddable":true,"href":"https:\/\/blog.proclima.com\/fr\/wp-json\/wp\/v2\/comments?post=325"}],"version-history":[{"count":8,"href":"https:\/\/blog.proclima.com\/fr\/wp-json\/wp\/v2\/posts\/325\/revisions"}],"predecessor-version":[{"id":374,"href":"https:\/\/blog.proclima.com\/fr\/wp-json\/wp\/v2\/posts\/325\/revisions\/374"}],"wp:attachment":[{"href":"https:\/\/blog.proclima.com\/fr\/wp-json\/wp\/v2\/media?parent=325"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blog.proclima.com\/fr\/wp-json\/wp\/v2\/categories?post=325"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blog.proclima.com\/fr\/wp-json\/wp\/v2\/tags?post=325"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}